X-ray Generator |
Type |
Super high frequency generator with automatic exposure control |
Safety protect |
With overload protection |
Frequency (output) |
460kHz |
Normal electric power |
50kW |
Exposure voltage kV |
40-150kV |
Exposure voltage precision |
±10% |
Exposure time |
1ms~8S |
Current |
10mA~640mA |
Current steps |
10mA, 12.5mA, 16mA, 20mA, 25mA, 32mA, 40mA, 50mA, 64mA, 80mA, 100mA, 125mA, 160mA, 200mA, 250mA, 320mA, 400mA, 500mA, 640mA |
Current time product |
0.1mAs ~ 640mAs |
Current time product steps |
0.1mAs; 0.125mAs; 0.16mAs; 0.2mAs; 0.25mAs; 0.32mAs; 0.4mAs; 0.5mAs; 0.64mAs; 0.8mAs; 1.0mAs; 1.25mAs; 1.6mAs; 2.0mAs; 2.5mAs; 3.2mAs; 4.0mAs; 5.0mAs; 6.4mAs; 8.0mAs; 10mAs; 12.5mAs; 16mAs; 20mAs; 25mAs; 32mAs; 40mAs; 50mAs; 64mAs; 80mAs; 100mAs; 125mAs; 160mAs; 200mAs; 250mAs; 320mAs; 400mAs; 500mAs; 640mAs |
Exposure mode |
Manual/AEC (Automatic Exposure Control) |
ARP |
≥1000 position |
Power input |
380/400/415/440V~ 3ph 50/60Hz±1Hz Power: MAX: 90kVA Standby:1kVA |
Radiation dose display |
DAP (optional) |
X-ray Tube Assembly |
Anode |
Rotating anode |
Target angle |
12° |
Min. focus input power |
22kW |
Max. focus input power |
54kW |
Input voltage |
40 ~ 150kV |
Max peak X-ray tube voltage |
150kV |
Max current range |
400/700 mA |
Nominal focal spot |
dual focus 0.6 mm/1.2 mm |
Anode heat storage capacity |
163kJ/230kHU |
Housing heat storage capacity |
975kJ /1354 kHU |
Max housing heat dissipation rate |
196W(272 HU/sec) |
Max anode heat dissipation rate |
750W (1056HU/sec) |
Cooling method |
Natural cooling |
Anode frequency |
50Hz/60Hz |
Anode rotation speed |
50Hz(2700r/min),60Hz(3200r/min) |
Inherent filtration |
1.3mmAl/75kV |
Weight |
16kg |
Collimator |
Type |
Manual collimator |
Beam shape |
Rectangular |
Inherent filtration |
1.0mmAI/70kV |
Full field light localizer |
Halogen light localizer |
Rotation degree |
-45°~ 45° |
Additional filtration |
0.5, 1.0, 1.5mm AI |
Detector |
Detector type |
Digital flat panel detector (mobile wired) |
Material |
Amorphous silicon (a-Si) semiconductor with cesium Iodide (CsI) scintillator |
Cooling method |
Natural cooling |
DQE |
>70% (0.1 lp/mm, RQA5) |
Pixel area (detector size) |
14 x 17.4inch / 35 x 43cm |
Pixel size |
143 μm |
Matrix size |
2448 x 2984 |
Dynamic range |
16 bit |
Spatial resolution |
3.7 lp/mm |
Imaging time of imaging system |
5s |
Preview time of imaging system |
2.5s |
Cycle time of imaging system |
6s |
Weight |
3.2kg |
Wire length |
9m |
Data transmission method |
Ethernet |
Wall Stand |
Type |
Bucky stand |
Detector assembly vertical travel range |
1450mm (350mm ~ 1800mm), ±5% |
SID |
1000 ~ 2000mm |
Movement method |
Manual |
Brake |
Mechanical |
X-ray Tube Assembly Support System |
Type |
Floor rails system |
Control mode |
Manual |
Tube assembly vertical travel range |
manual:1240 mm (560mm~1800mm), ±5% |
Tube assembly transverse motion |
manual: 1720mm, ±5% |
Movement method |
Manual |
Tube vertical axis rotation angle |
≥360° |
Tube horizontal axis rotation angle |
≥360° |
Tube tilting angle |
≥37°(-20°~17°) |
Patient table |
Type |
Stationary floating table |
Table size |
2120mm×825mm×650mm (length , width, height) |
Transparency equivalent (mmAI) |
≤1.2mmAl/100kV |
Table panel floating range |
trans:±130mm; logn:±450mm; (manual) |
Detector floating range |
logn:±290mm; (manual) |
Load capacity |
200kg |
Brake |
With footplate-brake on the wheels |
Chamber |
Type |
3-field ionization chamber |
Inherent filtration |
<0.7mmAl/75kV |
Voltage |
40kV~150kV |
Loading time |
0.5ms~10s |
Dose range |
0.174~174uGy |
Grid |
Type |
Fixed grid |
Focus |
1.0m+1.8m |
Grid ratio |
8:1 |
Line |
40L/cm |
Size |
470 x 450mm |